Explore Flipsnack. Transform boring PDFs into engaging digital flipbooks. Share, engage, and track performance in the same platform.
From magazines to catalogs or private internal documents, you can make any page-flip publication look stunning with Flipsnack.
Check out examples from our customers. Digital magazines, zines, ebooks, booklets, flyers & more.
Pre-made templates to create stunning publications in minutes
Here are eight reasons why you should consider choosing interactive, digital flipbooks instead of boring and static PDFs. Check them out!
NSF ® Certified to ANSI/NSF 61 4"–12" 16" MJ FIELD LOK ® Gasket 1. MJ FIELD LOK ® Gaskets are designed to seal and restrain a centrifugally cast Ductile Iron pipe in a Ductile Iron fitting bell. 2. MJ FIELD LOK Gaskets are available to fit mechanical joints conforming to ANSI/AWWA C111/A21.11 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings. 3. If Ductile Iron pipe with a lower pressure rating than the gasket is used, then the lower pressure rating will apply to the MJ FIELD LOK Gasket also. 4. MJ FIELD LOK Gaskets require 90 ft-lb of bolt torque for 4"–8" gaskets and 120 ft-lb of bolt torque for 10"–24" gaskets. Most common 1/2" drive air powered impact wrenches are capable of applying these torques. 5. U.S. Pipe does not recommend that the joints be deflected after the bolts have been tightened. 6. MJ FIELD LOK Gaskets are suitable for either potable water or wastewater applications. Lubricant is not recommended for the DI version of the MJ FIELD LOK Gasket during assembly. 7. MJ FIELD LOK Gaskets are NSF 61 Approved. 8. Series DI Gaskets are UL Listed for 350 psi in 4"–16" sizes. 9. MJ FIELD LOK Gaskets Series DI products are not recommended for use with cast iron pipe, plastic pipe, oversize pipe, metric pipe, or for use as a ‘transition’ gasket, or pipe with an O.D. coating of any kind that is thicker than 5 mils. Suggested Specifications: Joint restraint for mechanical joint pipe and fittings shall be the MJ FIELD LOK ® Gasket. The restraint system shall be completely integral to the gasket, requiring only standard mechanical joint assembly techniques. The restraining system for Ductile Iron shall be pressure rated to 350 psi in sizes up to and including 16". The pres- sure rating for DI restraints shall be based on a 2:1 safety factor or up to 350 psi depending on the class of the pipe used. MJ FIELD LOK ® Gasket Series DI PRESSURE APPROX. SIZE PIPE ORDER DEFLECTION RATING KIT Inches OD NUMBER Degrees psi WEIGHT 4 4.80 DI04 5 350 7.3 6 6.90 DI06 5 350 10.9 8 9.05 DI08 5 350 13.5 10 11.10 DI10 3 350 18.5 12 13.20 DI12 3 350 19.7 16 17.40 DI16 2 350 31.8 Application Notes: DIMENSIONS SIZE WEIGHT A B C D E Inches Pounds Outside Dia. Bolt Hole Inside Dia. OD Lip Gland Height 4 3.3 8.88 7.50 4.90 5.92 1.75 6 5.0 10.87 9.50 7.00 8.02 2.00 8 7.2 13.13 11.75 9.15 10.17 2.25 10 10.2 15.38 14.00 11.20 12.22 2.25 12 11.0 17.63 16.25 13.30 14.32 2.25 16 25.0 22.38 21.00 17.54 18.50 2.75 MJ FIELD LOK ® Gland (See illustration below.) USP36950 MJFL Submittal flyer.indd 2 8/19/14 3:43 PM
The cookies we use on Flipsnack's website help us provide a better experience for you, track how our website is used, and show you relevant advertising. If you want to learn more about the cookies we're using, make sure to check our Cookie policy
We use essential cookies to make our site work for you. These allow you to navigate and operate on our website.
We use performance cookies to understand how you interact with our site.They help us understand what content is most valued and how visitors move around the site, helping us improve the service we offer you.
We use marketing cookies to deliver ads we think you'll like.They allow us to measure the effectiveness of the ads that are relevant for you.